battery monitor bluetooth EJ-BC16 LiFePO4 SLA battery tester battery monitor rs485 OEM accepted

FOB Reference Price:Get Latest Price
  • 1 - 499 Pieces
    US$68.06
  • >=500 Pieces
    US$43.55
Lead Time:
Quantity(Pieces) 1 - 10 >10
Est. Time(days) 10 Negotiable
Customization:
Customized logo (Min. Order: 200 Pieces)
Samples:
US$68.06 /Pieces | 1 Pieces (Min. Order) | Buy Samples
Contact Supplier
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
EJ
Model Number:
EJ-BC16
Working Voltage:
10V - 120V
Shunt Working Current:
0A -500A
Size:
100 * 62 * 18mm
Packaging & Delivery
Port
Shenzhen
Lead Time :
Quantity(Pieces) 1 - 10 >10
Est. Time(days) 10 To be negotiated

EJ-BC16 Hight Precision LiFePo4 lead-acid battery, Nickel battery tester battery level indicator battery indicator monitor

EJ-BC16 is a kind of high accuracy current type battery indicator, EJ-BC16 can test the voltage, current, and capacity of the lead-acid/lithium-ion battery, and display them with intuitive battery symbol and percentage. Users can know the state of the battery in time. EJ-BC16 has the function of memory. This battery indicator is suitable for mobile and portable equipment, ups, electric vehicles, ebike, battery cars, balance cars, cleaning machines and so on.

EJ-BC16 is different with voltage type battery indicator, EJ-BC16 has high accuracy and high reliability.

Application:

EJ-BC16 battery indicator is suitable for lithium battery, lithium iron phosphate battery, lead-acid battery and nickel-metal hydride battery which voltage is from 10V to 120V.

Working interface:

Install:

  1. In the device panel to open a rectangular hole and two screw holes,
  1. Then install the battery indicator from the front of the panel and place the indicator housing into the rectangular opening;

Connect:

  1. Prepare a shielded wire and an ordinary wire (0.3-0.75 mm²);
  2. One end of the ordinary wire connects to B+ of the battery;
  3. Another end connects to B+ of the sampler (anyone is ok);
  4. The B- of sampler connects to B- of the battery;
  5. P- of sampler connect to P- of output;
  6. Finally, connect the sampler to the indicator by the shielded wire.

Attention: Please connect as shown strictly. The sampler must be connected to the negative circuit, it is forbidden to connect to the positive circuit. If you want to extend the shielded wire, you must use 4 lines of the same specification.

Use setting:

Capacity and voltage setting:

1. Press the “OK” key for 3s to enter the setting menu;

2. Click the “up” or“down” key to select the setting items:

CAP—capacity setting: an initial capacity has been set at the factory, please set it according to the real capacity;

FULL U—full voltage setting: when the voltage is higher than it the percentage will be 100%;

ZERO U—zero voltage setting: when the voltage is lower than it the percentage will be 0%, backlight off if you keep discharging the LCD flicker, the alarm indicator display, and buzzer warning;

Alarm—alarm setting: when the capacity is lower than it the LCD flicker and buzzer warning.

Note: Generally the FULL U and ZERO U do not need to set. The default is 0V, which is invalid. If you want to set, please understand the actual charge and discharge voltage of battery firstly.

3. Select“CAP”and click“OK”key to enter the capacity setting; The set bit flicker, click the“OK” key can select other bits, click the“up” or“down” key to plus and minus the value; after this click the“back”key to quit capacity setting;

4. We can set other items with the same method as capacity. When all the items are set and all the values are correct, click the “back” key to save the set and quit the setting menu;

5. Cut off and Re-power, it will work normally.